Menu

Product Center

FT8212S Desktop Simplified Power Supply PCBA Test System

Category: Low-Power Power Supply Test System

The FT8212S is a desktop simplified power supply PCBA test system developed by Dongguan Feisitaike based on the operating characteristics of low-power switching power supplies and market demand. It integrates no-load voltage, load voltage, and load current tests—previously requiring multiple instruments—into a single desktop device, transforming finished-product inspection on the power supply production line from “multiple machines and multiple lines” to “one machine, one station.”

Service Hotline
  • Product Details

Product Overview

The FT8212S is a desktop simplified power supply PCBA test system developed by Dongguan Feisitaike based on the operating characteristics of low-power switching power supplies and market demand. It integrates no-load voltage, load voltage, and load current tests—previously requiring multiple instruments—into a single desktop device, transforming finished-product inspection on the power supply production line from “multiple machines and multiple lines” to “one machine, one station.”

The system consists of a host unit and a test fixture.

The host unit has a built-in 12-channel low-power electronic load and a Windows industrial control system. The electronic load quickly measures the output voltage in the no-load state and the output voltage and current in the load state. The industrial control system uses a branded industrial motherboard to ensure stability during long-term continuous operation.

Test data is displayed directly on an 8-inch LVDS screen with a resolution of 800×600, allowing the host unit to be compact and refined without occupying extra space.

The host unit is equipped with dual power interfaces. One is the host operating power input (220V input); the other is the test power interface, which can be connected to the input power of the product under test as required. Inside the host unit, there are 12 independent explosion-proof lamps to prevent a product explosion from affecting adjacent stations.

The test fixture adopts a four-wire voltage sensing method to eliminate voltage line loss and ensure accurate test data. The fixture is pneumatically controlled to reduce operator fatigue. Dual start buttons ensure testing safety. The matching test box is patented by the company and can be replaced quickly within 20 seconds without any tools. After testing is completed, high-voltage capacitors are automatically discharged to prevent damage to other products.

For users, the value of the FT8212S is concentrated in three points: fast test cycle—the complete 12-channel process takes about 7 seconds, with the fastest single-unit time of 0.6 seconds; low investment cost—the price is approximately 20% of a 12-channel standard ATE bare-board test system and comparable to a standalone electronic load with the same number of channels; safety and data traceability—independent explosion protection per channel, automatic discharge after testing, and daily saving, statistics, and analysis of test quantities and results.


Core Functions and Advantages

Test Efficiency: Complete the Full 12-Channel Process in 7 Seconds

The complete test process for 12 channels is completed in about 7 seconds, with a speed of up to 0.6 seconds per unit. For the production line, this means the single-station cycle time is no longer a bottleneck. The operator’s loading and unloading time can cover the test time, so no additional personnel or buffer stations are needed for waiting for test results.


Accuracy and Reliability: 0.3% Accuracy, Four-Wire Sensing

Voltage and current accuracy reaches 0.3%. Combined with the four-wire voltage sensing method of the fixture, measurement deviation caused by voltage line loss is eliminated, making the test data closer to the true output of the product. The system adopts a modular design for easy maintenance, and the circuit has multiple protections with a low failure rate. Color-coded fool-proof connection cables ensure correct wiring and reduce misjudgment and rework caused by incorrect connection.


Safe Production: Independent Explosion Protection per Channel and Automatic Discharge

The host unit has 12 independent explosion-proof lamps built in. When a product explosion occurs at a single station, other channels are not affected. After testing, the system automatically discharges high-voltage capacitors to prevent charged products from flowing into the next process and damaging other products. The fixture uses dual start buttons; the operator must press both buttons simultaneously to start, eliminating accidental single-hand operation. When the fixture is pressed down, a relay self-locks the in-position signal to ensure that testing starts only after safe and correct positioning.


Changeover and Operation: 20-Second Test Box Change, Simple Program Editing

The patented test box supports quick replacement within 20 seconds without any tools, facilitating mixed-model production on multiple machines and the transportation and storage of test boxes. Program editing is simple and fast, and a large number of model files can be saved; when switching models, they can be called directly. Results are displayed with large icons arranged in a PCB layout, making viewing convenient and quick so that operators can locate defective positions at a glance.


Data Management: Automatic Statistics of Test Quantity and Results

The system has a test data statistics function and can save, count, and analyze daily test quantities and test results, providing a data basis for production yield tracking, batch traceability, and process improvement.


Structural Design: Compact and Space-Saving on the Production Line

The host unit integrates a 12-channel electronic load, an industrial control system, and an 8-inch LVDS display. It is compact overall and can be placed directly on a workbench or beside the production line without occupying additional line space. It is also easy to move as a whole when adjusting the production line layout.


Comparison of Three Multi-Channel Bare-Board Test Methods

In the PCBA bare-board test process of low-power switching power supplies, multi-channel parallel testing usually has three mainstream implementation methods: the combination of an electronic load and a test fixture, a standard ATE bare-board test system, and Feisitaike’s FT8212S desktop simplified test system. The three differ in price, test speed, degree of automation, and statistical capability. The following table compares them item by item from the perspective of practical use to help production lines make selection decisions based on their own cycle time and budget.


Price

Low price

Low price

The price is high

Test speed

Slow

Quick

Quick

Voltage remote testing

None

Yes

Yes

Discharge function

None

Yes

Yes

Test efficiency

Low

High

High

Statistical functions

None

Yes

Yes

Program settings

Set individually

Unified settings

Unified settings

Fixture method

Manual

Automatic

Automatic

Occupies space

Many

Few

Many

Labor intensity

High

Low

Low

AC power parameters

None

None

Yes


Technical specifications

The table below summarizes the main configurations and performance indicators of the FT8212S, all taken from product technical documentation.


Project

Specifications

Product model

FT8212S

Product type

Desktop simple power supply PCBA testing system

System composition

Main unit (12-channel electronic load + Windows industrial control system) + test fixtures

Number of test channels

12 channels

Test items

No-load output voltage, load output voltage, load output current

Voltage/current accuracy

0.3%

Test the beat

The entire 12-channel process takes about 7 seconds, with the fastest being 0.6 seconds per piece

Display

8-inch LVDS display with a resolution of 800×600

Host power supply

Dual power interfaces: Main unit working power input 220V; Connect the test power supply according to the requirements of the product under test

Safety protection

12-channel independent explosion-proof lamp; After testing, the high-voltage capacitor automatically discharges

Voltage acquisition method

Four-wire data collection eliminates voltage line losses

Fixture control

Pneumatic control, dual-button start, relay in position signal self-locking

Test kit

Patented test kit, replacement within 20 seconds, no tools required

Connecting cable

Color-separated foolproof design

Program management

The program is simple and fast to edit, capable of saving a vast number of machine file models

Data features

Daily test quantities and results are stored, compiled, and analyzed

Price positioning

About 20% of the price of a 12-channel standard ATE bare board test system


The table below further lists the FT8212S's resolution and accuracy indicators at rated inputs and in various operating modes

Used to evaluate the adaptability of the specific product under test

INPUT Rating 额定输入

Voltage: 0~30V

—

—

Current Current: 0~5A

—

—

Power: 0~45W

—

—

CC MODE Constant current mode

—

1mA

0.3%+0.5FS

CV MODE Constant voltage mode

—

1mV

0.3%+0.2FS

V Measurement 电压测量值

—

1mV

0.15%+0.3FS

I Measurement 电流测量值

—

1mA

0.15%+0.3FS


Application scenarios

FT8212S PCBA board-level testing for low-power switching power supplies, typical use cases include finished product inspection stations for low-power switching power supply production lines such as power adapters, chargers, and LED driver power supplies. On such production lines, product batches are large and the value per unit is low. The testing stage must ensure coverage without increasing the cost per test. FT8212S's 12-channel parallel operation perfectly matches this rhythm with the 7-second cycle.

In multi-machine mixed-line production, the patented test kit's 20-second tool-free change feature is especially practical: when changing models, you only need to replace the test kit for the corresponding model and call up the saved model program, without stopping the line for debugging or additional tools, making it suitable for flexible production arrangements with small batches and multiple varieties.

For companies that control shipment quality through spot checks or full inspections, the system's data statistics function can record test quantities and results daily, making it easier for quality departments to verify yield by batch, trace abnormal periods, and provide a basis for process parameter adjustments. The equipment itself is compact and can be placed directly on workbenches or next to assembly lines, suitable for small to medium-sized production lines with tight space and the need to quickly deploy testing capabilities.


Service and support

FT8212S Modular design with electronic loads, industrial control systems, and fixtures relatively independent, making daily maintenance and fault localization convenient. The circuit has multiple protections to reduce the risk of equipment damage caused by misoperation. As a patented kit, the test kit supports quick replacement and independent transport and storage, facilitating spare parts management by machine type. For specific matters such as equipment selection, model program configuration, fixture customization, and after-sales technical support, please contact Dongguan Festech directly. Technical staff will provide configuration advice based on the electrical characteristics of the tested product and production line schedule requirements.

Related Products
  • Business
    Phone: 13809631553 (Mr. Zhang)
    Email: ke.zhang@rmeter.cn
  • Technical Support
    Tel: 13688910500 (Mr. Sun)
    Email: chengdan.sun@rmeter.cn
  • After-sales Repair
    Tel: 13713127352 (Mr. Zhou)
    Email: hai.zhou@rmeter.cn
Copyright © RMETER   粤ICP备2026100643号
Copyright © RMETER
粤ICP备2026100643号
Sales
13809631553

After-sales service
13713127352